1. 現場反饋(Feed back):
1.1 K200 門機無強迫關門功能;
K200 door system has no the function of nudge closing ;
1.2 K200 門機編碼器和門機動力線無屏蔽層,編碼器干擾大;
There exist at too much disturb signal for the encoder because of havn’t the shield wire of motor
cable and the encoder cable;
1.3 K200 門機密碼經常進不去,門機參數丟失以及檢修狀態下開關門按鈕會出現失靈;
The password to control system of K200 are not available usally ,the control paramater have lost and
the open and colse door buttons can’t use when the door at the inspection mode;
1.4 關門過程中光幕被阻擋多次或門機被障礙物阻擋,導致失速撞門或門機脫離控制;
If cut the light curtain much times or keep blocking the door closed ,it will cause the fault running and
doors are knocked voilently;
1.5 門機門刀機械結構調整不到位,產生電梯運行時開門現象以及電梯消防層門易發生開門
不到位 情況;
The door vane mechanic system ajust not good ,it will cause to reopen the door during the lift start
running and the door of fire-risisted can’t open to the end of door width;
1.6 現場反映 K200 門機參數調試繁瑣;
There are too much adjusting parameters lead to testing difficulty ;
2. EC 測試和說明(Testing and clarification by EC):
2.1 K200 門機無強迫關門功能 (問題 1)。
K200 door system havn’t the function of nudge closing(Problem 1).
K200 門機系統作為標準配配置,無強迫關門功能。
In K200 door control system, nudging opertion is not a standard feature.
等級:C 頁碼:2/1
版本:A 更改碼:00
蒂森克虜伯電梯(中國區制造)
工程中心
K200 門機現場故障解決
指導書
(Instruct to solve the
problem for K200 door
system)
EC019-SS
生效日期:2009-06-23
注意(Note):
如果主板控制程序中設置了強迫關門功能,在門機被強行阻擋光幕的情況下會導致控制系統發出
強迫關門指令后無法按時收到門鎖接通信息,從而導致系統故障。
If there have the set the nudging running function at the mc2 control system,the mc2 control system will
sent the nudging order,but the door inverter havn’t accept and do the relative running at the light-curtain
is obstructed,it will cause the faultr.
處理方法(Solve methods):
請現場及時關閉 MC2 控制系統的強迫關門功能,在目前情況下,現場需要配置強迫關門功能,請
銷售人員請以非標項目進行訂單處理。
We suggest to close the MC2 control system nudging running function.If the customer need to add the
nudging running function ,please to deal with the order at special order.
2.2 K200 門機編碼器和門機動力線無屏蔽層,編碼器干擾大(問題 2):
There exist at too much disturb signal for the encoder because of havn’t the shield wire of motor
cable and the encoder cable(Problem 2):
編碼器干擾問題,已和 EC 試驗部的其他相關人員,對電梯運行過程中的編碼器信號,進行多
次的 HIOKI 示波器測定,根據測試的波形結果,編碼器波形穩定、清晰。另一方面根據現場反
饋的方法,在工地現場將門機編碼器和門機動力線臨時捆綁在一起,觀察運行電梯情況。測
試期間內電梯開關門運行正常,未發現動力線干擾編碼器的脈沖而影響門機運行。
To the encoder wired shield problem,the Testing & Filed support department have meaured the signal
of door motor encoder by the HIOKI wave recorder,The measued wave are stably and
clearly.According the feed back from the Branches,we are tight the power cable of door’s motor and
the encoder cable together,observe the elevator running ,the door system function are good ,the
distrubtion signal come form the motor power cable can’t affect the door control system to
distinguish encoder signal .
結論(Conclusion):
門機編碼器和門機馬達動力線不需增加屏蔽層。
We think that don’t need to add the shield level for the motor encoder cable .
等級:C 頁碼:3/1
版本:A 更改碼:00
蒂森克虜伯電梯(中國區制造)
工程中心
K200 門機現場故障解決
指導書
(Instruct to solve the
problem for K200 door
system)
EC019-SS
生效日期:2009-06-23
3. 機械機構問題處理(Mechanical problem Solution ):
門機馬達同步皮帶張力太低,門機轉動過程中導致皮帶轉動回差和滑齒現象,導致脈沖計數
誤差。
The tesion force for moter synchronous belt is too low , it will arise the belt jump teeth and
progressive error , cause the pulse count error to the door control system.
處理方法(Solve methods):
a) 不同類型和不同廳門寬度的 K200 門機,門機同步帶的張緊力有不同的設置要求,電梯在使
用過程中,同步帶會長度會延長,現場應根據同步帶松緊度表中的張力要求,定期檢查并調整
K200 門機的張緊度符合表中規定。
Different type and deferent width K200 door system ,the synchronous belt tension force have
different value.The belt will be lengthen during using time,so the site should be adjust the tension
force in time according the synchronous bele tenson force schedule .
b) 同步帶張緊力調整方法 、張緊力檢測方法、張緊力測試工具和同步帶松緊度表請參考附件
壓縮文件 2:(同步帶張緊力測試)。
About the Adjusting method of the synchorous belt ,Measure method of the tenson force for belt,The
measure tool tension force and The synchorous belt tension force standard sheet , Please to see the
attached winrar file 2 :( 同步帶張緊力測試).
備注(Note):
同步帶張力測試工具,分公司可以根據圖紙制作,或與 BST 公司進行采購。
The tools for the tension force examination ,can made according to the graph by the Branch ,also can
buy from BST .
等級:C 頁碼:4/1
版本:A 更改碼:00
蒂森克虜伯電梯(中國區制造)
工程中心
K200 門機現場故障解決
指導書
(Instruct to solve the
problem for K200 door
system)
EC019-SS
生效日期:2009-06-23
現場跟進事項(Need to followed by the site)!!!
正確調整擋塊位置。使廳門在完全關閉的位置時,掛鉤之間的間隙在 1-2mm 之間,這樣使
皮帶轉動過程順暢而無強大阻擋力產生,見圖(6)。
Right to adjust the position of the bar .The gap between tw hooks is 1-2mm when the door are
throughtly closed,the gap can lead the belt running smooth and havn’t cause big block
force,see( photo 6).
(圖片 6/Photo6)
4. 新時達門機變頻器軟件更新(Upgrade software for door invert by New Step):
4.1 門機變頻器軟件升級
新時達公司會采取更換變頻器控制板的方式升級門機控制軟件到最新版本。即對于版本號
FOO 顯示低于 250 15 的門機變頻器,軟件應立即升級, 具體由新時達公司提供門機變頻器主板,
于現場更換。請工廠客戶服務部門統計數量,聯系供應商并通知現場立即更換。具體更換注意
事項請參考附件 3-蒂森門機變頻器控制板更換。
The STEP will update the old version for K200 to the latest version by changed the inverter control
board .the inverter control board will changed immediately if the software are less than 250 15 by
New Step. It is need to statistics the quantity by the Customer Sevice Departmen,contact to the
supplier and imforma to site changed immediately. The attention please to see the attached file 3-蒂
森門機變頻器控制板更換.
間隙 1-2 毫米
等級:C 頁碼:5/1
版本:A 更改碼:00
蒂森克虜伯電梯(中國區制造)
工程中心
K200 門機現場故障解決
指導書
(Instruct to solve the
problem for K200 door
system)
EC019-SS
生效日期:2009-06-23
4.2 門機變頻器調試注意事項
1) 門機變頻器密碼(The password for door inverter):
請使用萬能密碼是:先輸入 L6902,再輸入 H3912,而后可操作修改參數。
Please use all-purpose password:First input L6902,next input H3912,then can operate the control
parameters.
2) 特殊參數及其事項(強制)
- F35 的參數必須改為“零”,以取消門機堵轉自動開門功能;
F35 should be set ‘0’ and canceled the auto-opened function when the door are blocked;
- 將 F37 參數 F37.2,F37.3 改為“常閉”觸點類型,將門機堵轉輸出串接到光幕回路,現場需要
根據附件 4-S9233 的配置更換電纜;
Change the F37.2,F37.3 to ‘NC’ in F37,connect the output signal of blocking running to the light
curtain circuit chain,please to refer the attached file 4-S9233 to change the right cable.
- 調整 MC2 控制系統 AF5A 的參數值為 3-4 秒,增大重開門時間值。
Adjust the reopen time is 3-4 S in AF5A of the MC2 control system .
現場調試參數列表(Site adjustment parameter table):
功能
碼 參數名稱 參數范圍 單位 出廠設置
F00 版本號+功能設定 1 / 199 / 9999 × 2501x
F04 門寬 0 ~ 60000 × 113
F08 關門到位百分比 0-15 × 8
F11 開門啟動低速 1 ~ 300 rpm 30
F12 關門啟動低速 1 ~ 300 rpm 30
F13 開門高速 1 ~ 1500 rpm 360
F14 關門高速 1 ~ 1500 rpm 315
F15 開門停止低速 1 ~ 300 rpm 40
F16 關門停止低速 1 ~ 300 rpm 30
F17 開門加速度 1 ~ 30 × 10
F22 開門爬行距離 1 ~ 30 % 10
等級:C 頁碼:6/1
版本:A 更改碼:00
蒂森克虜伯電梯(中國區制造)
工程中心
K200 門機現場故障解決
指導書
(Instruct to solve the
problem for K200 door
system)
EC019-SS
生效日期:2009-06-23
F23 關門爬行距離 1 ~ 30 % 2
F24 開門減速位置 50 ~ 100 % 63
F25 關門減速位置 1 ~ 50 % 40
F30 開門保持力矩大小 0 ~ 30 × 15
F31 關門保持力矩大小 0 ~ 30 × 7
F33 力矩保持時的速度 0 ~ 90 rpm 60
F34 v/f 控制時輸出力矩 0 ~ 40 % 25
F36 輸入類型設定 00000000~11111111 × 00000000
F37 輸出類型設定 0000 ~ 1111 × 0000
F91 初始化參數選擇 0 ~ 255 × 6
注意(CAUTION):
- 上表僅作參考,具體根據現場情況按安裝手冊調整。
Up sheet only for refer ,more adjust details to see the installation manual .
- 在門機同步皮帶張力調整到位的前提下,如發現門機頻繁發生自矯正慢速運行,建議在門寬自學
習后,檢查 F15 參數值,并將 F15 內的參數增大 10 或更大。
At the right adjustment of synchronous belt, if find the K200 door system do adjustment running very
frequently , we suggest to consult the parameter F15 value and decrease the value 10 or more.
- 增大/降低關門速度,需要同時增加/減小 F14, F25 的參數值。
Increase / decrease the closing speed , it need to increase /decrease the value in parameter F14 and F25
at one times .
- 增大/降低開門速度,需要同時增加/減小 F13, F24 的參數值,
Increase / decrease the opening speed ,it need to increase /decrease the value in parameter F13 and
F24 at one times
等級:C 頁碼:7/1
版本:A 更改碼:00
蒂森克虜伯電梯(中國區制造)
工程中心
K200 門機現場故障解決
指導書
(Instruct to solve the
problem for K200 door
system)
EC019-SS
生效日期:2009-06-23
3) 門機速度調整(Adjustment the door speed)
- 門機需要調整(復位)參數時,請先撥到檢修狀態;
Please turn the elevator to inspection mode when adjust (reset ) the control parameters;
- 設置 FOO=1,再根據需要修改相應的參數;
To change other parameters when needed should after to set the F00=1;
- 參數修改后請運行檢查,必要時重復上面動作;
Please to do the test running after the parameter has been changed; try do it again when needed;
- 門機調試完畢或門機切斷電源之前,設置 F00=199 保存參數,否則修改的調試參數會在重新
上電時丟失。
After change the door control parameter or turn off the door power ,it need to set F00=199 to save
the changed parameter, otherwise the parameter will be lost after the power turn on next.
4) 開、關門到位力矩保持調整 (Keeping torque of end position adjustment)
- 改變開、關門力距保持的力,可以通過修改 F30、F31、F33 等參數值;
It can be changed the value of parameter F30,F31,F33 to change the keeping torque of door end
position;
- 增大保持力時,要同時減少保持速度;反之,減小保持力,要同時增加保持速度。